21 research outputs found

    3D statistical shape analysis of the face in Apert syndrome

    Get PDF
    Timely diagnosis of craniofacial syndromes as well as adequate timing and choice of surgical technique are essential for proper care management. Statistical shape models and machine learning approaches are playing an increasing role in Medicine and have proven its usefulness. Frameworks that automate processes have become more popular. The use of 2D photographs for automated syndromic identification has shown its potential with the Face2Gene application. Yet, using 3D shape information without texture has not been studied in such depth. Moreover, the use of these models to understand shape change during growth and its applicability for surgical outcome measurements have not been analysed at length. This thesis presents a framework using state-of-the-art machine learning and computer vision algorithms to explore possibilities for automated syndrome identification based on shape information only. The purpose of this was to enhance understanding of the natural development of the Apert syndromic face and its abnormality as compared to a normative group. An additional method was used to objectify changes as result of facial bipartition distraction, a common surgical correction technique, providing information on the successfulness and on inadequacies in terms of facial normalisation. Growth curves were constructed to further quantify facial abnormalities in Apert syndrome over time along with 3D shape models for intuitive visualisation of the shape variations. Post-operative models were built and compared with age-matched normative data to understand where normalisation is coming short. The findings in this thesis provide markers for future translational research and may accelerate the adoption of the next generation diagnostics and surgical planning tools to further supplement the clinical decision-making process and ultimately to improve patients’ quality of life

    Skin measurement devices to assess skin quality:A systematic review on reliability and validity

    Get PDF
    Background Many treatments aim to slow down or reverse the visible signs of skin aging and thereby improve skin quality. Measurement devices are frequently employed to measure the effects of these treatments to improve skin quality, for example, skin elasticity, color, and texture. However, it remains unknown which of these devices is most reliable and valid. Materials and methods MEDLINE, Embase, Cochrane Central, Web of Science, and Google Scholar databases were searched. Instruments were scored on reporting construct validity by means of convergent validity, interobserver, intraobserver, and interinstrument reliability. Results For the evaluation of skin color, 11 studies were included describing 16 measurement devices, analyzing 3172 subjects. The most reliable device for skin color assessment is the Minolta Chromameter CR-300 due to good interobserver, intraobserver, and interinstrument reliability. For skin elasticity, seven studies assessed nine types of devices analyzing 290 subjects in total. No intra and interobserver reliability was reported. Skin texture was assessed in two studies evaluating 72 subjects using three different types of measurement devices. The PRIMOS device reported excellent intra and interobserver reliability. None of the included reviewed devices could be determined to be valid based on construct validity. Conclusion The most reliable devices to evaluate skin color and texture in ordinary skin were, respectively, the Minolta Chromameter and PRIMOS. No reliable device is available to measure skin elasticity in ordinary skin and none of the included devices could be determined to be designated as valid

    The Rainbow Scale for the Assessment of the Cervicomental Angle:A Validated Scale

    Get PDF
    Background: Aging of the neck results in an increased cervicomental angle, which can be treated by various surgical and nonsurgical procedures. To measure the success of these procedures, standardized validated objective photographic measurement tools are needed. However, no online standardized photographic measurement tools exist for the assessment of the cervicomental angle. Objectives: The purpose of this study was to establish a validated and reliable measurement tool for the assessment of the cervicomental angle based on the Rainbow Scale. Methods: A 5-point photographic rating scale was developed and created from 1 photograph with Adobe Photoshop. Fifteen reference photographs of women, 3 photographs per grade, were included for validation. Seven panelists (ie, plastic and maxillofacial surgeons) assessed the reference photographs 3 times with a minimal interval of 3 days in an online survey. Intra- and inter-observer agreements were calculated utilizing the weighted kappa coefficient. Results: Mean intra-observer agreement was 0.93 (0.78-1.00). Mean interobserver agreement was 0.796 (0.574-0.961) for survey 1, 0.868 (0.690-0.960) for survey 2, and 0.820 (0.676-0.959) for survey 3. Conclusions: The Rainbow Scale for the assessment of the cervicomental angle has been validated in an online fashion. The scale is reproducible and reliable and requires no learning curve. Potential applications include objective assessment of neck treatment planning and surgical outcome

    Reply:The Effects of Facial Lipografting on Skin Quality: A Systematic Review

    Get PDF
    BACKGROUND: Autologous lipografting for improvement of facial skin quality was first described by Coleman in 2006. The current dogma dictates that adipose tissue-derived stromal cells that reside in the stromal vascular fraction of lipograft contribute to skin rejuvenation (e.g., increased skin elasticity), a more homogenous skin color, and softening of skin texture. Nowadays, many studies have been reported on this "skin rejuvenation" effect of autologous fat grafting. This systematic review was undertaken to assess the efficacy of autologous lipografting on skin quality.METHODS: The MEDLINE, Embase, Cochrane Central, Web of Science, and Google Scholar databases were searched for studies evaluating the effect of autologous lipografting on facial skin quality (May 11, 2018). Outcomes of interest were skin texture, color, and elasticity in addition to histologic outcomes and number of complications.RESULTS: Nine studies were included, with 301 patients treated in total. No meta-analysis could be performed because of heterogeneity of the metrics and outcomes. Eight studies reported increased skin elasticity; improvement in skin texture; and a more homogeneous skin color after treatment with lipografting, cellular stromal vascular fraction, or nanofat. One study reported no increased skin elasticity after lipografting. Histologic improvement was seen after lipografting and adipose tissue-derived stromal cell injections. However, in general, the level of evidence of the included studies was low. No serious complications were reported.CONCLUSION: Autologous facial lipografting and cellular stromal vascular fraction and adipose tissue-derived stromal cell injections hardly seem to improve facial skin quality but can be considered a safe procedure.</p

    Growth patterns and shape development of the paediatric mandible – A 3D statistical model

    Get PDF
    BACKGROUND/AIM: To develop a 3D morphable model of the normal paediatric mandible to analyse shape development and growth patterns for males and females. METHODS: Computed tomography (CT) data was collected for 242 healthy children referred for CT scan between 2011 and 2018 aged between 0 and 47 months (mean, 20.6 ± 13.4 months, 59.9% male). Thresholding techniques were used to segment the mandible from the CT scans. All mandible meshes were annotated using a defined set of 52 landmarks and processed such that all meshes followed a consistent triangulation. Following this, the mandible meshes were rigidly aligned to remove translation and rotation effects, while size effects were retained. Principal component analysis (PCA) was applied to the processed meshes to construct a generative 3D morphable model. Partial least squares (PLS) regression was also applied to the processed data to extract the shape modes with which to evaluate shape differences for age and sex. Growth curves were constructed for anthropometric measurements. RESULTS: A 3D morphable model of the paediatric mandible was constructed and validated with good generalisation, compactness, and specificity. Growth curves of the assessed anthropometric measurements were plotted without significant differences between male and female subjects. The first principal component was dominated by size effects and is highly correlated with age at time of scan (Spearman's r = 0.94, p < 0.01). As with PCA, the first extracted PLS mode captures much of the size variation within the dataset and is highly correlated with age (Spearman's r = −0.94, p < 0.01). Little correlation was observed between extracted shape modes and sex with either PCA or PLS for this study population. CONCLUSION: The presented 3D morphable model of the paediatric mandible enables an understanding of mandibular shape development and variation by age and sex. It allowed for the construction of growth curves, which contains valuable information that can be used to enhance our understanding of various disorders that affect the mandibular development. Knowledge of shape changes in the growing mandible has potential to improve diagnostic accuracy for craniofacial conditions that impact the mandibular morphology, objective evaluation, surgical planning, and patient follow-up

    Latent Disentanglement in Mesh Variational Autoencoders Improves the Diagnosis of Craniofacial Syndromes and Aids Surgical Planning

    Full text link
    The use of deep learning to undertake shape analysis of the complexities of the human head holds great promise. However, there have traditionally been a number of barriers to accurate modelling, especially when operating on both a global and local level. In this work, we will discuss the application of the Swap Disentangled Variational Autoencoder (SD-VAE) with relevance to Crouzon, Apert and Muenke syndromes. Although syndrome classification is performed on the entire mesh, it is also possible, for the first time, to analyse the influence of each region of the head on the syndromic phenotype. By manipulating specific parameters of the generative model, and producing procedure-specific new shapes, it is also possible to simulate the outcome of a range of craniofacial surgical procedures. This opens new avenues to advance diagnosis, aids surgical planning and allows for the objective evaluation of surgical outcomes

    Skin Measurement Devices to Assess Skin Quality

    No full text

    Skin measurement devices to assess skin quality: A systematic review on reliability and validity

    No full text
    Background: Many treatments aim to slow down or reverse the visible signs of skin aging and thereby improve skin quality. Measurement devices are frequently employed to measure the effects of these treatments to improve skin quality, for example, skin elasticity, color, and texture. However, it remains unknown which of these devices is most reliable and valid. Materials and methods: MEDLINE, Embase, Cochrane Central, Web of Science, and Google Scholar databases were searched. Instruments were scored on reporting construct validity by means of convergent validity, interobserver, intraobserver, and interinstrument reliability. Results: For the evaluation of skin color, 11 studies were included describing 16 measurement devices, analyzing 3172 subjects. The most reliable device for skin color assessment is the Minolta Chromameter CR-300 due to good interobserver, intraobserver, and interinstrument reliability. For skin elasticity, seven studies assessed nine types of devices analyzing 290 subjects in total. No intra and interobserver reliability was reported. Skin texture was assessed in two studies evaluating 72 subjects using three different types of measurement devices. The PRIMOS device reported excellent intra and interobserver reliability. None of the included reviewed devices could be determined to be valid based on construct validity. Conclusion: The most reliable devices to evaluate skin color and texture in ordinary skin were, respectively, the Minolta Chromameter and PRIMOS. No reliable device is available to measure skin elasticity in ordinary skin and none of the included devices could be determined to be designated as valid

    Computational modelling of patient specific spring assisted lambdoid craniosynostosis correction

    Get PDF
    Lambdoid craniosynostosis (LC) is a rare non-syndromic craniosynostosis characterised by fusion of the lambdoid sutures at the back of the head. Surgical correction including the spring assisted cranioplasty is the only option to correct the asymmetry at the skull in LC. However, the aesthetic outcome from spring assisted cranioplasty may remain suboptimal. The aim of this study is to develop a parametric finite element (FE) model of the LC skulls that could be used in the future to optimise spring surgery. The skull geometries from three different LC patients who underwent spring correction were reconstructed from the pre-operative computed tomography (CT) in Simpleware ScanIP. Initially, the skull growth between the pre-operative CT imaging and surgical intervention was simulated using MSC Marc. The osteotomies and spring implantation were performed to simulate the skull expansion due to the spring forces and skull growth between surgery and post-operative CT imaging in MSC Marc. Surface deviation between the FE models and post-operative skull models reconstructed from CT images changed between ± 5 mm over the skull geometries. Replicating spring assisted cranioplasty in LC patients allow to tune the parameters for surgical planning, which may help to improve outcomes in LC surgeries in the future
    corecore